Center of container type dataPolaris Polaris seriesProduct introductionCenter of type data of container of series of Polaris” of Polaris of Zhi Ting &ldqu
Polaris Polaris series
Center of type data of container of series of Polaris” of Polaris of Zhi Ting “ is prefab unifinication solution of infrastructure of center of the data outdoor, center of container type data IT machine ark, distribution, air conditioning, fire control, how to prevent, the part of data center infrastructure such as monitoring or entirely compositive installation arrive container of freight of a standard (20 feet or 40 feet) inside, thereby compose builds a height the data center of a variety of compositive, agile extend, function utility; Differ according to functional type, center of container type data already can monomer moves independently, also can take the kind of building blocks ” through “ , build all sorts of dimensions data centers neatly.

?
The rapid development that drove data center industry as upsurge of calculative of Internet, big data, cloud, in course of all sorts of burgeoning IT development, its are final be born needs infrastructure level prop up, realize promotion application truly through counting those who occupy central territory to change. Zhi Ting borrows force to be accumulated at the technical experience of center of data of 20 years of deep ploughing, can offer the infrastructure solution that group of a variety of center of contented container data change, implementation factory is modular prefab, the spot is fast deploy consign.
Group of pile of monomer container product
Zhi Tingneng offers 20 feet, 40 feet reach blame demarcate to make casing wait for product of center of monomer container data, each monomer product can satisfy all function of data center. The pile that carries monomer product is patulous, every — the distributed only point that monomer container product makes center of integral group data, center of data of container of either sheet dot malfunctions the container data center that won't affect other sheet to nod moves, tall fault tolerance, Gao Ke leans.
Group of pile of container of different function module
Special group changes container data center to serve as a whole, differentiate to divide container of group of a few unit models the monomer that is different function according to the function, unit model group eachs doing his own job, undertake redundant fault tolerance is configured, undertake group changes pile next. Design a standard according to GB50174 data center, differentiate for
Group of model of division of group of group of group of auxiliary division model, dynamical division model, refrigeration division model, equipment.
Assist division model group: Room of spare parts of well of well of division of office of stair well, administration, conduit, strong weak report, ventilating shaft, machine parts or tools kept in reserve, medium accuse box.
Group of dynamical division model: Between batteries, between distribution, store can box, transformer box, bavin sends case.
Group of refrigeration division model: Refrigeration box, harbour cold box, condensation box, new bellows.
Group of equipment division model: Server box, memory box, network equipment box.
According to different spot condition and client demand, the group that Zhi Tingneng provides all sorts of custom-built place to need to the client is changed solve square examine.
?
Apply to computation of electronic government affairs, cloud, IDC (Internet data center) , company for private use, marine division is taken an examination of, transformer substation of calculation of oil gas exploration, military operation, margin, intelligence, super- calculate a center, a variety of application such as computer room of node of net of couplet of scientific research center, content setting.
?
?
|
Model |
40ft of Polaris Polaris series- - standard edition |
40ft of Polaris Polaris series- - Plus money |
|||
|
Overall |
Casing norms (L*W*H)mm |
12192*2438*2896 |
12192*3000*3200 |
||
|
Measure of IT machine cabinet |
8 |
10 |
10 |
14 |
|
|
Machine ark parameter |
1. norms: 600*1000/1200*20002. Cabinet put oneself in another's position is used 10 fold profile to solder type frame assembles a structure, important bearing the component uses 2.0mm aluminous zine plate of thick high grade Fu is made, the others component uses 1.2mm armor plate of thick high grade cold rolling is made; 3. Machine cupboard front door uses sheet to open door of plain net of aluminium alloy frame, postern double open mesh door, make sure door plank is not out of shape; 4. Machine ark bottom offers two ground connection to nod, soft lead joins between door body and cabinet put oneself in another's position, machine ark receives terrestrial electricity block to answer < 0.05Ω . |
||||
|
Stand-alone ark power (KW) |
≥5 |
||||
|
IT laden general power (KW) |
≥40 |
≥50 |
≥50 |
≥70 |
|
|
Waterproof and dustproof |
Mark matchs IP55 |
||||
|
Aseismatic grade |
9 intensity are aseismatic |
||||
|
Working temperature |
- 20 ℃ ~ + 55 ℃ |
||||
|
Electric |
Input power source makes type |
Three-phase 4 lines + PE, 380V/400V/415V, 50Hz/60Hz |
|||
|
Unifinication UPS ark |
Ark of 1. unifinication UPS supports input of double power source, ATS switch device, will modular UUPS, UPS is inputted / the unifinication such as output distribution, IT distribution, air conditioning distribution, illume distribution is compositive inside machine ark, have simple Yi Wei to protect, dependability is mixed high efficient and managing characteristic; 2. Unifinication UPS ark defends grade: IP40; 3. Configuration B class prevents surge protector; 4. Distribution ark has monitoring function. |
||||
|
Prevent thunder grade |
Imax is not less than 80kA (8/20µs) |
||||
|
UPS allows gauge division |
≥60KVA |
≥75KVA |
≥75kVA |
≥100kVA |
|
|
UPS configuration |
2N, N+1, N |
||||
|
Mothball accumulator |
Support battery of lithium of iron of plumbic acerbity accumulator, phosphoric acid |
||||
|
Mothball time |
Not under 15min |
||||
|
Air conditioning |
Allocate buy for nothing |
Air conditioning of nicety of class of wind cold travel |
|||
|
25kW/ stage
(2+1 is redundant) |
25kW/ stage
(3+1 is redundant) |
25kW/ stage
(3+1 is redundant) |
25kW/ stage
(4+1 is redundant) |
||
|
The machine outdoor installs the position |
Alone storehouse of the machine outdoor is installed |
Container coping is installed |
Alone storehouse of the machine outdoor is installed |
Container coping is installed |
|
|
Make cryogen |
R410A |
||||
|
Cold heat is kept apart |
Contented, cold passageway ≥1000mm/ heats up passageway ≥600mm |
Contented, cold passageway ≥900mm/ heats up passageway ≥700mm |
|||
|
Air conditioning system |
Supportive wind is refrigeration of pump of cold, fluorine, water-cooling, refrigerant the system such as water |
||||
|
Air conditioning fittings |
Microtherm component, lengthen package to wait |
||||
|
Prevent thunder ground connection |
Prevent thunder |
Contented " the building prevents thunder to design a standard " GB50057 - 2010 requirements |
|||
|
Ground connection |
Combine ground connection system, the protective ground connection, job ground connection, ground connection that prevent thunder is common ground connection body, ground connection resistance is less than 1 ohm |
||||
|
How to prevent |
Entrance guard |
Dactylogram password reads card implement the pass in and out of the means administrator of test and verify |
|||
|
Video monitoring |
Container interior, exterior area realizes video monitoring not to have blind angle |
||||
|
Monitoring parameter |
Mobile carry dimension |
Support dimension of carry of APP long-range shift, unmanned value is defended |
|||
|
Monitoring function |
Support government of asset, capacity, space, specific power consumption |
||||
|
Fire control parameter |
Fire calls the police automatically system |
Supportive fire is extremely inchoate aerosol calls the police (optional) |
|||
|
Extinguishing system |
7 fluorine propane / complete fluorine personal ketone |
||||