Ark of unifinication UPS distributionProduct introductionArk of brand-new distribution of UPS of unifinication of wisdom the court of a feudal ruler is the best
Ark of brand-new distribution of UPS of unifinication of wisdom the court of a feudal ruler is the best distribution plan of IT system, pay close attention to the electric energy quality that changes subtly to manage, the IT load of center of data of convenient client basis and company grow demand, upgrade and run distribution system.
Height of ark of unifinication UPS distribution is compositive modular module of distribution of spur track of module of module of power source of UPS, input, UPS distribution module, air conditioning distribution, IT within cabinet put oneself in another's position, the exterior and machine ark match, have economic space, Yi Wei to protect, dependability is advanced characteristic.



|
Project |
Norms description |
|
|
Configuration parameter |
Nominal capacity |
30 ~ 150KVA |
|
Input means |
Only way power supply / two-way power source is inputted (ATS) |
|
|
Input norms |
160/200/250/400A |
|
|
IT distribution |
24 × of 32A/1P × 2 |
|
|
Distribution of illume of air conditioning \ |
32A/3P × 6 or 63A/3P × 4, 40A/3P × 2; 16A/1P × 6 |
|
|
Breaker |
Outside dividing special specification, 63A and the following breaker adopt miniature breaker entirely, 63A above adopts model carapace breaker |
|
|
Input parameter |
Input rated voltage |
380V/400V/415V (line voltage) ; 3Ph+N+PE |
|
Input voltage limits |
38 ~ 485Vac |
|
|
Input frequency limits |
40-70HZ |
|
|
Power input factor |
> 0.99 |
|
|
Output parameter |
Rated voltage |
380V/400V/415V(line voltage) |
|
Rated frequency |
50/60Hz |
|
|
Output voltage harmonic (THDV) |
) of linear load of ≤ 2% (; ≤ 5% (is nonlinear laden) |
|
|
Power factor |
1 |
|
|
Peak value comparing |
3: 1 |
|
|
Overload ability |
Laden ≤ 110% , 60min, ≤ 125% , maintain 10min, ≤ 150% maintain 1min, ≥ 150% turn instantly bypass |
|
|
Monitoring |
Communication function |
RS485, TCP/IP (optional) |
|
Touch screen |
7 inches, 10 inches |
|
|
Monitoring content |
The of each moving parameter such as capacity of condition of frequency of output of input of voltage of 1.UPS input output, UPS, UPS, batteries
The parameter such as wave of harmony of the switch condition of input of 2. distribution system and each IT laden spur track, voltage, electric current, n, power |
|
|
Systematic parameter |
Overall efficiency |
95.5% |
|
IP defends grade |
IP40 |
|
|
Communication prevents thunder |
20KV, 8/20 μ S |
|
|
Environment |
Environmental temperature |
40 ℃ of 0 ℃ ~ |
|
Storage temperature |
- 55 ℃ of 25 ℃ ~ (do not contain batteries) |
|
|
Humidity limits |
0 ~ 95% (not condensation) |
|
|
Working height above sea level |
<1500m (exceed 1500m to fall by GB/T 3859.2 regulation the forehead is used) |
|
|
Noise (DB) (1 meter distance) |
<61dB |
|
|
Over all dimension |
× 2000mm of 600mm × 1200mm |
|