Central space uses abnormity layout data to be put with equipment optimize

Center of abnormity layout data: The space is used put with equipment optimize
In current informatization times, data center regards business information as systematic core, its space uses what put with equipment to optimize what matter to data center directly to run efficiency, specific power consumption and expansibility. The space around center of abnormity layout data uses article general to be put with equipment optimize undertake be discussinged deep.
One, the advantage of center of abnormity layout data
1.Raise dimensional utilization rate
With traditional rectangle layout photograph is compared, center of abnormity layout data is used in the space on have clear advantage. Abnormity layout can be mixed according to building construction field condition, adjust equipment to put neatly, make full use of space, reduce data center to build cost.
2.Optimize air current organization
Center of abnormity layout data is helpful for optimizing air current organization, rise medicinal powder thermal efficiency. Adopt reasonable design, can make cold air from fall to flow up, hot air from go up to be discharged downward, form good air current loop, drop equipment temperature, lengthen service life of equipment.
3.Improve carry dimension efficiency
Center of abnormity layout data is put in equipment on more agile, facilitating equipment is safeguarded and expand. The course is maintained in equipment in, OK and fast fixed position arrives breakdown equipment, decrease defend time, improve carry dimension efficiency.
2, the space is used optimize strategy
1.Area of sound program equipment
Mix according to equipment type, power comsumption medicinal powder hot demand, differentiate equipment for many area, wait like division of server area, equipment of memery block, network. In program process, the associated sex between mature equipment, ensure the data between equipment is transmitted expedite.
2.Optimize passageway design
The passageway is the join ligament between equipment, reasonable design passageway conduces to raise dimensional utilization rate. Passageway design should satisfy the following requirement:
(1) passageway width should satisfy equipment to carry with carry dimension demand;
(2) passageway position should keep away from equipment comes loose hot blind angle, ensure air current is expedite;
(3) connect principle amount to answer enough, prevent facility concentrated area is embraced.
3.Make full use of perpendicular space
The process is put in equipment in, make full use of perpendicular space, if use memory of type of vertical server, frame,wait. In addition, can consider to set equipment area in data center coping, raise dimensional utilization rate.
3, equipment is put optimize strategy
1.Density of reasonable arrangement equipment
Mix according to equipment power comsumption medicinal powder hot demand, density of reasonable arrangement equipment. In equipment concentrated area, can consider to use medicinal powder the equipment with hot better performance or increase medicinal powder hot equipment, ensure equipment moves normally.
2.Optimize facilities distribution
The process is put in equipment in, between mature equipment medicinal powder hot demand, ensure to certain distance maintains between equipment. In the meantime, according to equipment type and function, equitable distribution facilities, raise dimensional utilization rate.
3.Use equipment management system
Run a system through equipment, real time supervisory equipment runs state, discover in time and resolve equipment trouble. Equipment management system is OK still according to equipment performance and power comsumption, optimize facilities distribution, improve performance of data center whole.
4, summary
Center of abnormity layout data is used in the space put a respect to have clear advantage with equipment. Put with equipment through optimizing a space to use, can raise data center to run efficiency, reduce specific power consumption, provide stable, efficient data service for the enterprise. In the development henceforth, center of abnormity layout data will make the fundamental trend that data center builds.
More News
2026-09-18
Construction of center of 800V dc data is in large center calculating force to apply
2026-09-18
Plan of liquid cooling of AI data center builds cost and carry dimension analysis
2026-09-18
Plan of liquid cooling of AI data center is energy-saving fall bad news and PUE are optimized
2026-09-18
AI wisdom calculates a center to build plan in installment allow strategy with stretch enlarge
Get the solution
Leave your contact information for immediate access to relevant solutions
Get the solution