Channel of center of data of double platoon small module closes to manage with air current
Center of data of double platoon small module: Channel of center of data of double platoon small module closes to manage with air current
As the flying development of IT, data center regards business information as the center of memory and processing, its importance is highlighted increasingly. Center of data of double platoon small module regards a kind of efficient, energy-saving, safe data as central solution, got pay close attention to extensively. The article will close to spread out development to discuss with air current management around channel of center of data of double platoon small module.
One, overview of center of data of double platoon small module
Center of data of double platoon small module is a kind of modular, data center solution that can expand. It waits for server, memory, network equipment compositive in the machine ark that standardizes in, pass modular design, implementation is quick disposition, quick expand and efficient managing. Center of data of double platoon small module has the following characteristic:
1.Efficient and energy-saving: Use come loose advancedly hot technology and energy-saving equipment, reduce specific power consumption, raise energy utilization rate.
2.On the safe side: Adopt multiple and safe preventive measure, ensure stability of data center security moves.
3.Modular design: Facilitate quick disposition is mixed patulous, satisfy the demand that the company increases ceaselessly.
4.Management is convenient: Run a system through concentration, implementation equipment monitoring, breakdown is diagnosed, function is optimized wait for a function.
2, channel of center of data of double platoon small module closes
The passageway closes is one of main character of center of data of double platoon small module. The passageway closes can prevent cold hot air current effectively to mix, improve refrigeration efficiency, reduce specific power consumption. It is the dot of a few keys that the passageway closes below:
1.Cold hot passageway is detached: Will cold hot air current is detached, avoid cold hot air current to mix, improve refrigeration efficiency.
2.The passageway closes material: Use the data with the superior performance such as fire prevention, dustproof, sound insulation, ensure the passageway closes the effect.
3.The passageway closes design: Reasonable design passageway closes structure, ensure air current is smooth, reduce resistance.
4.The passageway closes construction: Ask strictly to undertake construction according to the design, ensure the passageway closes the effect.
3, management of air current of center of data of double platoon small module
Air current management is one of crucial technologies of center of data of double platoon small module. Rational air current management can improve refrigeration efficiency, reduce specific power consumption, lengthen service life of equipment. A few keys that are air current management below nod:
1.Cold hot air current is detached: Close through the passageway, realize cold hot air current to depart, improve refrigeration efficiency.
2.Air current organization: Reasonable design air current is organized, ensure cold steam sheds smooth flow, reduce resistance.
3.Fan layout: Equitable distribution fan, implementation air current distributings equably, improve refrigeration result.
4.Wind force control: According to effective demand, adjust fan wind force, implementation is energy-saving fall bad news.
4, the applied value of center of data of double platoon small module
Center of data of double platoon small module has value of the following application:
1.Raise energy utilization rate: Close to shed management compatibly through the passageway, reduce specific power consumption, raise energy utilization rate.
2.Raise equipment dependability: Adopt the design of on the safe side, ensure equipment stability moves, lower fault rate.
3.Satisfy business demand: Modular the design facilitates quick disposition is mixed patulous, satisfy the demand that the company increases ceaselessly.
4.Reduce operation cost: Can fall through the section bad news, reduce operation cost, enhance company competition ability.
Anyhow, center of data of double platoon small module closes to have distinct advantage with field of air current management in the passageway. The enterprise should pay close attention to the technical development of this one domain, make full use of pair of character that discharge center of small module data, improve performance of data center whole, for the enterprise development provides strong safeguard.