Message 中文版
room level precision air conditioning
Room level air conditioning
Full stack self-developed
High reliability architecture
Quick Deployment
Ultimate Energy Saving

Air conditioning of nicety of class of HM series room basically is computer room of big, medium, small-sized data to offer control of high accuracy temperature and humidity, have efficient and energy-saving, adaptability strong, on the safe side, modular

Contact
Scroll down
Product data

Air conditioning of nicety of class of HM series room

Product introduction

Air conditioning of nicety of class of HM series room basically is computer room of big, medium, small-sized data to offer control of high accuracy temperature and humidity, have efficient and energy-saving, adaptability strong, on the safe side, modular design, intelligence management, structure compact, craft is masterly, economic space, satisfy the cooling requirement of contemporary data computer room in the round.

Use an occasion

Environment of wet craft of constant of room of control of room of equipment of medical treatment of computer room of data center and room of the scheming in applying at each domain, computer room, communication equipment, network computer room, industry and accurate treatment facilities, constant temperature / store environment, UPS and batteries.

Product characteristic

This series product has L wind is cold model, water-cooling, refrigerant water, cold quantity enclothes 7 ~ 200kW, satisfy all sorts of circumstances different bear demand.
Control of L microcomputer intelligence ensures the system is best move, refrigeration system classifications design, leng Liangzhi can adjust.
Compressor of L efficient vortex, oscillatory small, noise is low reach dependability advanced characteristic, use agent of refrigeration of R410A environmental protection.
L7 inch exceed trends of big feeling screen to show aircrew runs state in real time, graph figure shows parameter of temperature and humidity changes.
Technology of net of group of LCAN bus line, group control amount amounts to 32, call the police automatically and diagnose a function perfectly, all-around the ground protects air-conditioner group.
L mark matchs PTC report to heat, wet film is added wet, on the safe side, energy-saving and efficient.
L uses EC wind force of centrifugal fan implementation is successive and adjustable, match thermic load neatly, by need to supply, green is energy-saving.
Electron of L high accuracy expands a powerful person, degree of superheat of agent of accurate control refrigeration, evaporate pressure and capacity, maintain Gao Leng to measure output.
15% wide electrified wire netting get used to L support ± , anthology match redundant distribution, prevent type of thunder, rope / function of sensor of the leach that choose form.
Fan of condensation of the L aircrew outdoor has function of stepless speed regulation, self-adjusting movement speed, cover an area of an area small.

The machine outdoor

Technical parameter- - refrigerant water series

Parameter
Model
ZT-HM040C
ZT-HM060C
ZT-HM100C
ZT-HM120C
ZT-HM180C
ZT-HM200C
ZT-HM180C
ZT-HM200C
Wind force
M3/h
8000
13000
19000
25000
35000
36000
35000
37500
Operating mode one (GB operating mode) : Indoor operating mode: DB24 ℃ / RH50% , temperature of water of pass in and out 7 ℃ / 12 ℃ ;
Operating mode one
Refrigerating capacity
KW
43.7
59.7
97.8
114.8
167.9
191.8
171.3
205.3
Show cold amount
KW
34.2
49.2
77.8
93.8
135.2
149
137.4
156.8
Discharge
M3/h
7.6
10.7
17.4
21
30.4
34.6
31.2
36.6
Hydraulic fall
KPa
100
95.5
110.3
110.5
112.1
107.9
117.9
122.6
Operating mode 2: Indoor operating mode: DB28 ℃ / RH40% , temperature of water of pass in and out 10 ℃ / 15 ℃ ;
Operating mode 2
Refrigerating capacity
KW
39.1
60.1
99.8
120.2
180.2
200.3
180.2
200.3
Show cold amount
KW
37.6
57.7
95.8
115.3
173
192.3
173
192.3
Discharge
M3/h
6.7
10.3
17.2
20.6
30.9
34.3
30.9
34.3
Hydraulic fall
KPa
80.8
69.8
71.4
69.8
81.3
94.2
81.3
94.2
Operating mode 3: Indoor operating mode: DB30 ℃ / RH40% , temperature of water of pass in and out 12 ℃ / 18 ℃ ;
Operating mode 3
Refrigerating capacity
KW
38.6
53.7
87.5
103.4
150.8
170.2
153.4
179.8
Show cold amount
KW
36.8
53.5
84.5
102.4
147.3
161.7
149.5
169.9
Discharge
M3/h
5.7
8.1
13
15.9
22.8
25.8
23.3
27.3
Hydraulic fall
KPa
55.3
55.2
62.5
64
64.6
60.7
66.3
69
Operating mode 3: Indoor operating mode: DB30 ℃ / RH40% , temperature of water of pass in and out 15 ℃ / 21 ℃ ;
Operating mode 3
Refrigerating capacity
KW
29.9
42.1
67.5
80.8
117.3
131.3
119.3
138.5
Show cold amount
KW
29.4
42.1
67.5
80.8
117.3
131.3
119.3
138.5
Discharge
M3/h
4.4
6.4
10.2
12.6
18
20.2
18.2
21.2
Hydraulic fall
KPa
34
35.6
40
40.9
41.7
38
42.2
43
Operating mode 4: Indoor operating mode: DB35 ℃ / RH40% , temperature of water of pass in and out 18 ℃ / 24 ℃ ;
Operating mode 4
Refrigerating capacity
KW
34.8
49.7
79.1
95.3
137.7
153.2
139.9
161.2
Show cold amount
KW
34.8
49.7
79.1
95.3
137.7
153.2
139.9
161.2
Discharge
M3/h
5.1
7.5
11.8
14.6
21
23.3
21.2
24.5
Hydraulic fall
KPa
45
47.2
51.5
54
53.9
49.3
54.8
55.6
Report adds quantity of heat
KW
6
6
9
9
12
12
12
12
Increase wet amount
Kg/h
4.5
4.5
6.5
6.5
10
10
10
10
FLA of peak load electric current
A
14.7
14.7
24.8
24.8
34.9
34.9
34.9
34.9
Over all dimension
Wide
Mm
900
900
1800
1800
2550
2550
2700
2700
Deep * is tall
Mm
1000*1980
Weight
Kg
320
330
600
620
850
865
905
920

Technical parameter- - series of straight Peng type

Model
ZT-HM030-A
ZT-HM045- A
ZT-HM060- A
ZT-HM090- A
ZT-HM120- A
Parameter
Indoor operating mode: DB35 ℃ / RH30% , the operating mode outdoor: DB35 ℃
Refrigerating capacity
KW
32.4
45.2
62.7
90.4
125.1
Show cold amount
KW
32.4
45.2
62.7
90.4
125.1
Indoor operating mode: DB24 ℃ / RH50% , the operating mode outdoor: DB35 ℃
Refrigerating capacity
KW
25.1
40.5
50.5
80.6
100.9
Show cold amount
KW
24.2
36.9
45.8
73.4
91.8
Wind force
M3/h
9000
11000
13000
22000
26000
Report adds quantity of heat
KW
6
9
9
9
9
Increase wet amount
Kg/h
6
6
10
10
10
Peak load electric current
A
49.7
62.2
69.2
110.8
124.8
Weight
Kg
280
328
391
633
790
Over all dimension
Mm
1100*1000*2000
1100*1000*2000
1100*1000*2000
2200*1000*2000
2200*1000*2000
(Wide * deep * is tall)
Flat type parameter of the machine outdoor
Model
ZT-50NP
ZT-60NP
ZT-80NP
ZT-60NP
ZT-80NP
Match an amount
Stage
1
1
1
2
2
Fan amount
1
2
2
4
4
Dimension of the machine outdoor (wide * deep * is tall)
Mm
1650*1100*1150
2010*1100*1150
2700*1100*1150
2010*1100*1150
2700*1100*1150
Collect Chinese style (fluorine pump) parameter of the machine outdoor
Model
ZT-SW50NVHMP
ZT-SW70NVHMMP
ZT-SW90NVHMP
ZT-SW70NVHMP
ZT-SW90NVHMP
Match an amount
Stage
1
1
1
2
2
Fan amount
1
1
1
2
2
Dimension of the machine outdoor (wide * deep * is tall)
Mm
1080*1080*1745
1080*1080*1745
1080*1080*1874
1080*1080*1745
1080*1080*1874
Note:
1) compressor of vortex of full frequency conversion, cold intermediary of R410A environmental protection.
2) power source makes type: 380V, 3N, 50Hz.
3) on aircrew of frequency conversion of class of room sending wind but custom-built outside the greatest opportunity beyond press 450Pa, the biggest add 36kW of quantity of heat, most substantially wet quantity 15kg/h, if demand contacts Zhi Ting please.
4) wind sends below aircrew of room class frequency conversion the canal goes out below acquiesce, wind sends acquiesce on left give a canal (next compatible going out canal) .
5) because the product is improved,upgrade need, if parameter changes excuse me not to inform separately, before ordering goods, affirm please.

Technical parameter- - nature of pump of double loop fluorine cools series

Model
ZT-HM030P
ZT-HM045P
ZT-HM060P
ZT-HM090P
ZT-HM120P
Parameter
Indoor operating mode: DB35 ℃ / RH30% , the operating mode outdoor: DB35 ℃
Refrigerating capacity
KW
32.4
45.2
62.7
90.4
125.1
Show cold amount
KW
32.4
45.2
62.7
90.4
125.1
Indoor operating mode: DB24 ℃ / RH50% , the operating mode outdoor: DB35 ℃
Refrigerating capacity
KW
25.1
40.5
50.5
80.6
100.9
Show cold amount
KW
24.2
36.9
45.8
73.4
91.8
Wind force
M3/h
9000
11000
13000
22000
26000
Report adds quantity of heat
KW
6
9
9
9
9
Increase wet amount
Kg/h
6
6
10
10
10
Peak load electric current
A
49.7
62.2
69.2
110.8
124.8
Weight
Kg
320
330
340
670
680
Over all dimension
Mm
1100*1000*2000
1100*1000*2000
1100*1000*2000
2200*1000*2000
2200*1000*2000
(Wide * deep * is tall)
Flat type parameter of the machine outdoor
Model
ZT-50NP
ZT-60NP
ZT-80NP
ZT-60NP
ZT-80NP
Match an amount
Stage
1
1
1
2
2
Fan amount
1
2
2
4
4
Dimension of the machine outdoor (wide * deep * is tall)
Mm
1650*1100*1150
2010*1100*1150
2700*1100*1150
2010*1100*1150
2700*1100*1150
Collect Chinese style (fluorine pump) parameter of the machine outdoor
Model
ZT-SW50NVHMP
ZT-SW70NVHMMP
ZT-SW90NVHMP
ZT-SW70NVHMP
ZT-SW90NVHMP
Match an amount
Stage
1
1
1
2
2
Fan amount
1
1
1
2
2
Dimension of the machine outdoor (wide * deep * is tall)
Mm
1280*1080*2200
1280*1080*2200
1280*1080*2200
1280*1080*2200
1280*1080*2200
Energy-saving module parameter (match flat the machine outdoor is used)
Energy-saving module model
ZT-SW50FHM
Power
W
≤ 500
Dimension (wide * deep * is tall)
Mm
780*350*1000
Note:
1) compressor of vortex of full frequency conversion, cold intermediary of R410A environmental protection.
2) mark of the machine outside double loop series matchs fluorine pump, when taking fluorine pump function, derive for series of groovy frequency conversion.
3) power source makes type: 380V, 3N, 50Hz.
4) on aircrew of frequency conversion of class of room sending wind but custom-built outside the greatest opportunity beyond press 450Pa, the biggest add 36kW of quantity of heat, most substantially wet quantity 15kg/h, if demand contacts Zhi Ting please.
5) wind sends below aircrew of room class frequency conversion the canal goes out below acquiesce, wind sends acquiesce on left give a canal (next compatible going out canal) .
6) because the product is improved,upgrade need, if parameter changes excuse me not to inform separately, before ordering goods, affirm please.


Related Products
Product Features&Advantages
High reliability
99.999% availability, N+X redundancy, meets GB50174 A/B class standards
Fully self-developed
Micro-modules / UPS / Air Conditioning / Power Distribution / Liquid Cooling / DCIM - Fully independently developed and produced
>
Quick Deployment
Factory prefabrication, on-site assembly, 60% reduction in delivery cycle
High-efficiency and energy-saving
AI energy saving, cold and hot isolation, liquid cooling, PUE as low as 1.15
Five-star after-sales service
National network of branches, 7x24 response, full lifecycle operation and maintenance services
Own factory
30,000 sq m production base, standardized quality control, supports customized production
Solutions
Government agencies
Financial Industry
Public Security, Procuratorate, Court, and Justice Department
Power industry
Medical institution
Educational Research
Enterprise IDC
Operator/Base Station
Supercomputing / Intelligent Computing / Liquid Cooling
Overseas containers
 


Get the solution
Leave your contact information for immediate access to relevant solutions
Get the solution