Message 中文版
UPS
Machine posture UPS-6KVA
Full stack self-developed
High reliability architecture
Quick Deployment
Ultimate Energy Saving

UPS of type of ZT-HR series frame Power limits Power limits: 6kVA Working way

Contact
Scroll down
Product data

UPS of type of ZT-HR series frame

Power limits

Power limits: 6kVA

Working way

Sheet goes out into sheet, double commutation is online work

Use range

Apply extensively at Wu of government, finance, communication, education, traffic, atmosphere, broadcasting television, industrial and commercial duty, medical treatment each industries such as electric power of sanitation, the sources of energy domain

Function characteristic

Realize of online double changeover truly
Microprocessor controls a technology to assure high reliability
Power input factor is corrective
Output power factor 0.8
Wide input voltage (110 V comes 300 V)
Efficient frequency conversion changes mode
ECO mode provides energy-saving result (be confined to 1-3K machine to plant compatible dynamo is inputted)
Charging current of lasting effect type amounts to 6A

Technical parameter

Machine kind
ZT-HR1101(S)L
ZT-HR1102(S)L
ZT-HR1103(S)L
ZT-HR1106(S)L
ZT-HR1110(S)L
Phasic
Single-phase ground connection
Capacity
1000VA / 800 W
2000VA / 1600 W
3000VA / 2400 W
6000VA / 4800 W
10000VA / 8000 W
Input
Rated voltage
100/110/115/120/127VAC? Or 200/208/220/230/240VAC
208/220/230/240VAC
Voltage limits
55-145VAC or 110-300 VAC at 50% laden
85-140VAC or 160-280 VAC at 100% load
110-300VAC ± 3% at 50% laden
176-300VAC ± 3% at 100% load
Frequency limits
40Hz? ~ 70 Hz
46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power factor
≧ 0.99 @ 100% is laden
Output
Rated voltage
100/110/115/120/127VAC? Or 200/208/220/230/240VAC
208/220/230/240VAC
Voltage limits? (Batteries mode) )
± 1%
± 1%
Frequency limits? (Synchronous and corrective limits)
47~ 53 Hz or 57 ~ 63 Hz
46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency limits (batteries mode)
500.25 Hz of Hz ± or 0.3 Hz of 60Hz ±
500.1 Hz of Hz ± or 0.1 Hz of ± of 60 Hz
Voltaic wave Zuo is compared
3: 1
Harmonic is lack fidelity
Linear of ≦ 3 % THD (is laden) 5 % THD (of; ≦ is nonlinear laden)
Linear of ≦ 3 % THD (is laden) 5 % THD (of; ≦ is nonlinear laden)
Changeover time
Town report mode turns batteries mode
Without
Inversion comes bypass
4 millisecond? (Below standard condition)
0 millisecond
Undee (batteries mode)
Sterling bowstring wave
Efficiency
Town report mode
88%
89%
90%
92%
93%
Batteries mode
83%
87%
88%
90%
91%
Batteries
Standard machine
Cell type
12V / 9 AH
12V / 9 AH
12V / 9 AH
12V / 9 AH
Amount
2
4
6
16
20
16
20
The standard charges time
4 hours are filled to 90%
9 hours are filled to 90%
The biggest charging current
1.0A (the biggest)
Set beforehand: 1.0 A, the biggest. : 2.0A
Charge voltage
27.4VDC ± 1%
54.7VDC ± 1%
82.1VDC ± 1%
218.4VDC ± 1%
273VDC ± 1%
218.4VDC ± 1%
273VDC ± 1%
Grow effect machine
Cell type
Match according to actual application many batteries box
Amount
2
3
4
6
6
8
16 ~ 20 (but Zha is whole)
The biggest charging current
1.0A/2.0A/4.0A/6.0 A
1A/2A/4A/6A (can be adjusted, 6A applies to 16 batteries only)
Charge voltage
27.4VDC ± 1%
41.0VDC ± 1%
54.7VDC ± 1%
82.1VDC ± 1%
82.1VDC ± 1%
109.4VDC ± 1%
218.4VDC ± 1% (be based on 16)
Indication specification
LCD Or LED shows
Laden size, ? Batteries capacity, town report mode, batteries mode, ? Bypass mode, breakdown directive
Warn sound
Batteries mode
Every 4 seconds ring
Batteries n is low
Every 1 second rings
Overload
Every 1 second rings
Breakdown
Resound continuously
Physical function
StandardMachine
Dimension, deep X wide X is tall (Mm)
310 X 438 X 88 [2U]
410 X 438 X 88 [2U]
630 X 438 X 88 [2U]
Lead plane:
530x438x88? [2U]
Batteries is covered:
668x438x88? [2U]
Lead plane:
530x438x88? [2U]
Batteries is covered:
580x438x133? [2U]
Lead plane: 580x438x133 [3U]
Batteries is covered:
580x438x133 [3U]
Suttle (kilogram)
12
19
29.3
Lead plane: 15
Batteries covers: 48
Lead plane: 15
Batteries covers: 61
Lead plane: 18
Batteries covers: 51
Lead plane: 18
Batteries covers: 61
Grow effectMachine
Dimension, deep X wide X is tall (Mm)
310 X 438 X 88 [2U]
410 X 438 X 88 [2U]
500 X 438 X 88 [2U]
580 X 438 X133 [3U]
Suttle (kilogram)
9
12
14.2
15
18
Use environment
humidity
Relative humidity 20-90 % and spends C (of 0- 40 ° not to written guarantee dew)
Relative humidity 0-95 % and spends C (of 0- 40 ° not to written guarantee dew)
Noise
Little at rice of 50dBA @ 1
Little at rice of 55dBA @ 1
Little at rice of 58dBA @ 1
Control management
Optional USB of intelligent RS-232 /
Support Windows? 2000/2003/XP/Vista/2008, windows? 7/8, linux, unix, and MAC
Optional SNMP
Power source management supports SNMP management and network government


Related Products
Product Features&Advantages
High reliability
99.999% availability, N+X redundancy, meets GB50174 A/B class standards
Fully self-developed
Micro-modules / UPS / Air Conditioning / Power Distribution / Liquid Cooling / DCIM - Fully independently developed and produced
>
Quick Deployment
Factory prefabrication, on-site assembly, 60% reduction in delivery cycle
High-efficiency and energy-saving
AI energy saving, cold and hot isolation, liquid cooling, PUE as low as 1.15
Five-star after-sales service
National network of branches, 7x24 response, full lifecycle operation and maintenance services
Own factory
30,000 sq m production base, standardized quality control, supports customized production
Solutions
Government agencies
Financial Industry
Public Security, Procuratorate, Court, and Justice Department
Power industry
Medical institution
Educational Research
Enterprise IDC
Operator/Base Station
Supercomputing / Intelligent Computing / Liquid Cooling
Overseas containers
 


Get the solution
Leave your contact information for immediate access to relevant solutions
Get the solution