UPS of type of tower of ZT-HT33 series 10-180kVA Product introduction ZT-HT33 10-180kVA is control of total number word online double

Contact
Scroll down
Product data

UPS of type of tower of ZT-HT33 series 10-180kVA

Product introduction

ZT-HT33 10-180kVA is control of total number word online double changeover 3 enter 3 UPS, have overall efficiency factor of tall, power input harmonic of electric current of tall, input quality of low, output is outstanding wait for an advantage, can remove issues of all sorts of electrified wire netting, provide stable, reliable power source protection for the client.

Use a field

The enterprise is medium or small data center, how to prevent branch of system, banking, traffic to attemper the center.

Function characteristic

Dependability tall
Exceed range of wide input voltage, get used to of environment of abominable electrified wire netting
Input frequency range is big, can receive fuel dynamo
Efficient green
Overall efficiency is more than be equal to 95.5%
Power input factor is as high as 0.99, input harmonic electric current is less than 3%
Practical strong
Exceed strong belt to carry ability, laden adaptability is strong, compatible the dynamo runs
Support 4 paralell connection and common batteries group
Use sexual good easily
Optional 4.3 inches of color touch screen, operate easily
Intelligence governs a function, support of interface of RS485, SNMP, dry node, CAN

Technical parameter

Model
ZT-HT33010XL
ZT-HT33020XL
ZT-HT33030XL
ZT-HT33040XL
ZT-HT33060X
ZT-HT33080X
ZT-HT33100X
ZT-HT33120X
ZT-HT33160X
ZT-HT33180X
Nominal capacity
10kVA
20kVA
30kVA
40kVA
60kVA
80kVA
100kVA
120kVA
160kVA
180kVA
Input
Wiring makes type
Three-phase 5 lines
Rated input voltage
380/400/415Vac
Input voltage limits
110-300VAC, laden 50%;176-276VAC, 100% load
138~485Vac
Input frequency limits
40Hz-70Hz
Power input factor
≥ 0.99
Harmonic of input electric current (THDi)
≤ 3%(100% linear is laden)
Bypass voltage limits
- 30%~+20%(is adjustable)
220Vac upper limit: 25% (optional + 10% , + 15% , + 20% ) 230Vac upper limit: 20% (optional + 10% , + 15% ) 240Vac upper limit: 15% (optional + 10% ) floor level: - 45%(is optional - 10% , - 20% , - 30% )
The dynamo is received
Support
Output
Wiring makes type
Three-phase 5 lines
Rated output voltage
380/400/415Vac
Output power factor
0.9
Voltage precision
± 1%
Frequency
Synchronous limits: 46 ~ 54Hz or 56 ~ 64Hz
Batteries mode: 50/60Hz ± 1%
Town report mode: 5% ± of ± of 4%/ of ± of 2%/ of ± 1%/ ± 10% can set; batteries pattern: (50/60 ± 0.1%)Hz
Voltaic peak value is compared
3:1(Maximum)
Output voltage harmonic (THDV)
≦ 1%THD(linear is laden) ; ≦ 3%THD (nonlinear laden)
≤ 2% (100% linear are laden) 4% of; ≤ (100% nonlinear laden)
Overall efficiency
Communicate / ECO/ batteries mode: 96.0%
95.50%
Overload ability
100-110%60 minute, 111-125%10 minute, 126%-150%1 minute; > 150%400ms
110% load, bypass turns after 60min continuously; 125% load, bypass turns after 10min continuously; 150% load, bypass turns after 1min continuously
Batteries
Batteries voltage
Depend on exterior batteries (32-40 section is adjustable) / 3x400V(3 photograph + N line)
Section of 300Vdc(30-50 of ± of 288/ of ± of 276/ of ± of 264/ of ± of 252/ of ± of 240/ of ± of 228V/ of ± of 216V/ of ± of 204V/ of ± 180V/192V/ ± is optional)
Charging current
1A~12A is adjustable
The biggest 10A
The biggest 15A
The biggest 20A
The biggest 30A
The biggest 45A
Switch time
Town report mode turns bypass mode: 0ms(dogs) ; Town report mode turns batteries mode: 0Ms
Environment
Working temperature
40 ℃ of 0 ℃ ~
Storage temperature
- 55 ℃ of 25 ℃ ~
Humidity limits
0 ~ 95% (not condensation)
Working height above sea level
<1500 meters
Noise (1 meter of distances)
Be less than 65dB @1 rice
<55dB
<58dB
<60dB
<65dB
Function
Function of give an alarm
Breakdown of unusual, UPS, batteries owes report of overload, town pressure wait for functions of a variety of give an alarm
Protect a function
Batteries is owed pressure, output is owed too pressure, breakdown of too short circuit, overload, lukewarm, fan calls the police, prevent thunder
Communication interface
CAN, RS485, FE, LBS, and adapter of machine card, SNMP (anthology match) , relay gets stuck (anthology match)
Other
Dimension (H of × of D × W) Mm
592x250x576
720x250x535
868x250x862
885x440x1200
Suttle (Kg)
38
40
35
38
70.5
150
160
162
196
198
Executive standard
YD/T 1095-2008


Related Products
Product Features&Advantages
High reliability
99.999% availability, N+X redundancy, meets GB50174 A/B class standards
Fully self-developed
Micro-modules / UPS / Air Conditioning / Power Distribution / Liquid Cooling / DCIM - Fully independently developed and produced
>
Quick Deployment
Factory prefabrication, on-site assembly, 60% reduction in delivery cycle
High-efficiency and energy-saving
AI energy saving, cold and hot isolation, liquid cooling, PUE as low as 1.15
Five-star after-sales service
National network of branches, 7x24 response, full lifecycle operation and maintenance services
Own factory
30,000 sq m production base, standardized quality control, supports customized production
Solutions
Government agencies
Financial Industry
Public Security, Procuratorate, Court, and Justice Department
Power industry
Medical institution
Educational Research
Enterprise IDC
Operator/Base Station
Supercomputing / Intelligent Computing / Liquid Cooling
Overseas containers
 


Get the solution
Leave your contact information for immediate access to relevant solutions
Get the solution