UPS of type of tower of ZT-HT33 series 10-180kVA Product introduction ZT-HT33 10-180kVA is control of total number word online double
ZT-HT33 10-180kVA is control of total number word online double changeover 3 enter 3 UPS, have overall efficiency factor of tall, power input harmonic of electric current of tall, input quality of low, output is outstanding wait for an advantage, can remove issues of all sorts of electrified wire netting, provide stable, reliable power source protection for the client.
Model | ZT-HT33010XL | ZT-HT33020XL | ZT-HT33030XL | ZT-HT33040XL | ZT-HT33060X | ZT-HT33080X | ZT-HT33100X | ZT-HT33120X | ZT-HT33160X | ZT-HT33180X | |
Nominal capacity | 10kVA | 20kVA | 30kVA | 40kVA | 60kVA | 80kVA | 100kVA | 120kVA | 160kVA | 180kVA | |
Input | Wiring makes type | Three-phase 5 lines | |||||||||
Rated input voltage | 380/400/415Vac | ||||||||||
Input voltage limits | 110-300VAC, laden 50%;176-276VAC, 100% load | 138~485Vac | |||||||||
Input frequency limits | 40Hz-70Hz | ||||||||||
Power input factor | ≥ 0.99 | ||||||||||
Harmonic of input electric current (THDi) | ≤ 3%(100% linear is laden) | ||||||||||
Bypass voltage limits | - 30%~+20%(is adjustable) | 220Vac upper limit: 25% (optional + 10% , + 15% , + 20% ) 230Vac upper limit: 20% (optional + 10% , + 15% ) 240Vac upper limit: 15% (optional + 10% ) floor level: - 45%(is optional - 10% , - 20% , - 30% ) | |||||||||
The dynamo is received | Support | ||||||||||
Output | Wiring makes type | Three-phase 5 lines | |||||||||
Rated output voltage | 380/400/415Vac | ||||||||||
Output power factor | 0.9 | ||||||||||
Voltage precision | ± 1% | ||||||||||
Frequency | Synchronous limits: 46 ~ 54Hz or 56 ~ 64Hz
Batteries mode: 50/60Hz ± 1% | Town report mode: 5% ± of ± of 4%/ of ± of 2%/ of ± 1%/ ± 10% can set; batteries pattern: (50/60 ± 0.1%)Hz | |||||||||
Voltaic peak value is compared | 3:1(Maximum) | ||||||||||
Output voltage harmonic (THDV) | ≦ 1%THD(linear is laden) ; ≦ 3%THD (nonlinear laden) | ≤ 2% (100% linear are laden) 4% of; ≤ (100% nonlinear laden) | |||||||||
Overall efficiency | Communicate / ECO/ batteries mode: 96.0% | 95.50% | |||||||||
Overload ability | 100-110%60 minute, 111-125%10 minute, 126%-150%1 minute; > 150%400ms | 110% load, bypass turns after 60min continuously; 125% load, bypass turns after 10min continuously; 150% load, bypass turns after 1min continuously | |||||||||
Batteries | Batteries voltage | Depend on exterior batteries (32-40 section is adjustable) / 3x400V(3 photograph + N line) | Section of 300Vdc(30-50 of ± of 288/ of ± of 276/ of ± of 264/ of ± of 252/ of ± of 240/ of ± of 228V/ of ± of 216V/ of ± of 204V/ of ± 180V/192V/ ± is optional) | ||||||||
Charging current | 1A~12A is adjustable | The biggest 10A | The biggest 15A | The biggest 20A | The biggest 30A | The biggest 45A | |||||
Switch time | Town report mode turns bypass mode: 0ms(dogs) ; Town report mode turns batteries mode: 0Ms | ||||||||||
Environment | Working temperature | 40 ℃ of 0 ℃ ~ | |||||||||
Storage temperature | - 55 ℃ of 25 ℃ ~ | ||||||||||
Humidity limits | 0 ~ 95% (not condensation) | ||||||||||
Working height above sea level | <1500 meters | ||||||||||
Noise (1 meter of distances) | Be less than 65dB @1 rice | <55dB | <58dB | <60dB | <65dB | ||||||
Function | Function of give an alarm | Breakdown of unusual, UPS, batteries owes report of overload, town pressure wait for functions of a variety of give an alarm | |||||||||
Protect a function | Batteries is owed pressure, output is owed too pressure, breakdown of too short circuit, overload, lukewarm, fan calls the police, prevent thunder | ||||||||||
Communication interface | CAN, RS485, FE, LBS, and adapter of machine card, SNMP (anthology match) , relay gets stuck (anthology match) | ||||||||||
Other | Dimension (H of × of D × W) Mm | 592x250x576 | 720x250x535 | 868x250x862 | 885x440x1200 | ||||||
Suttle (Kg) | 38 | 40 | 35 | 38 | 70.5 | 150 | 160 | 162 | 196 | 198 | |
Executive standard | YD/T 1095-2008 | ||||||||||